DocumentCode :
781726
Title :
A Family of Interleaved DC–DC Converters DeducedFrom a Basic Cell With Winding-Cross-CoupledInductors (WCCIs) for High Step-Upor Step-Down Conversions
Author :
Li, Wuhua ; He, Xiangning
Author_Institution :
Coll. of Electr. Eng., Zhejiang Univ., Hangzhou
Volume :
23
Issue :
4
fYear :
2008
fDate :
7/1/2008 12:00:00 AM
Firstpage :
1791
Lastpage :
1801
Abstract :
A basic cell with winding-cross-coupled inductors (WCCIs) and interleaved structure is proposed in this paper. A family of DC-DC converters is deduced from the proposed basic cell, which is suitable for high step-up or step-down conversions. The passive-lossless clamp scheme is derived from the active clamp scheme to recycle the leakage energy and to suppress the voltage spikes caused by the leakage inductance. The advantages of the derived interleaved boost converter with WCCIs and passive-lossless clamp circuits are analyzed as an example. The voltage gain is extended and the switch voltage stress is reduced to minimize the conduction losses. The rectifier reverse-recovery problem is alleviated by the leakage inductance. Furthermore, a series of DC-DC converters with WCCIs and passive-lossless clamp circuits are summarized for high efficiency, high power and high step-up or step-down applications. A clear picture is made in this paper on the general law and structure of the WCCIs for DC-DC conversion in high step-up or step-down applications. At last, the simulated and experimental results of a 1 kW 40 V-to-380 V prototype with WCCIs and passive-lossless clamp circuits verify the significant improvements in performance.
Keywords :
DC-DC power convertors; inductors; interleaved DC-DC converters; interleaved boost converter; leakage inductance; passive-lossless clamp scheme; power 1 kW; rectifier reverse-recovery problem; step-down conversion; step-up conversion; voltage 40 V to 380 V; voltage spikes suppression; winding-cross-coupled inductors; Circuit analysis; Clamps; DC-DC power converters; Inductance; Inductors; Rectifiers; Recycling; Stress; Switches; Voltage; Basic cell; passive-lossless clamp; winding-cross-coupled inductor (WCCI);
fLanguage :
English
Journal_Title :
Power Electronics, IEEE Transactions on
Publisher :
ieee
ISSN :
0885-8993
Type :
jour
DOI :
10.1109/TPEL.2008.925204
Filename :
4558240
Link To Document :
بازگشت