• DocumentCode
    782830
  • Title

    Study of MOV operator and motor characteristics to determine torque capability

  • Author

    Hussain, B. ; Behera, A.K. ; Alsammarae, A.J.

  • Author_Institution
    KCI Engineering Consultants, Downers Grove, IL, USA
  • Volume
    42
  • Issue
    6
  • fYear
    1995
  • fDate
    12/1/1995 12:00:00 AM
  • Firstpage
    2271
  • Lastpage
    2274
  • Abstract
    Motor operated valves (MOVs) used in the nuclear generating stations require the high torque capability of a motor when demanded during an accident scenario. This paper specifically deals with the behavior and classification of motors used in AC MOVs. This paper also deals with a methodology that may be consistently applied to determine the realistic capability (that is, rating) of the motor/operator. As an ongoing resolution to the NRC IEB 89-10 issue of the impact of degraded voltage condition and other environmental conditions on torque capability of the MOVs, the determination of appropriate motor torque capability is essential
  • Keywords
    AC motors; fission reactor cooling; torque; valves; AC motor operated valves; NRC IEB 89-10; accident; degraded voltage condition; motor; nuclear power stations; torque capability; AC motors; Accidents; Actuators; Character generation; Degradation; Manufacturing; Nuclear power generation; Pistons; Torque; Valves;
  • fLanguage
    English
  • Journal_Title
    Nuclear Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9499
  • Type

    jour

  • DOI
    10.1109/23.489426
  • Filename
    489426