• DocumentCode
    782910
  • Title

    N16 Power Control System of the Livermore Pool-Type Reactor

  • Author

    Spracklen, Howard P.

  • Author_Institution
    University of California, Lawrence Radiation Laboratory Livermore, California
  • Volume
    14
  • Issue
    1
  • fYear
    1967
  • Firstpage
    271
  • Lastpage
    274
  • Abstract
    A power level indicating and control system that is independent of rod position and gamma background was developed for the Livermore Pool-Type Reactor (LPTR). This system, based on the N16 decay in the primary coolant water, avoids the errors in ion-chamber measurements caused by changes in leakage flux, related to fuel loading, fuel burnup, xenon buildup, and rod position. A scintillation detector was placed near the coolant outlet. A dual differential discriminator monitors the output and drives a counter in the control room. The numerical readout is directly in watts. The counter output provides a control signal that can override the ion-chamber control when an error exists. The system operates from 2 MW down to 2 kW under automatic control.
  • Keywords
    Automatic control; Control systems; Coolants; Fuels; Inductors; Position measurement; Power control; Radiation detectors; Scintillation counters; Xenon;
  • fLanguage
    English
  • Journal_Title
    Nuclear Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9499
  • Type

    jour

  • DOI
    10.1109/TNS.1967.4324426
  • Filename
    4324426