DocumentCode :
782988
Title :
Impulse Breakdown and Power-Frequency Partial Discharge Inception Voltages of Insulating Liquids
Author :
Cesari, S. ; Yakov, S.
Author_Institution :
ENEL, Centro di ricerca Elettrica Cologno Monzese, Italy
Issue :
2
fYear :
1985
fDate :
4/1/1985 12:00:00 AM
Firstpage :
315
Lastpage :
319
Abstract :
Test procedures used in power-frequency and impulse tests on dielectric liquids are discussed in the paper, The voltage stress relative to a given test procedure is represented as a combination of a certain number of "elementmentary stresses". Then, on the basis of rather simple theoretical consideraticons, the partial discharge inception (or breakdown) probability related to the test procedure is expressed as a function of the probability associated with the "elementary stress". In this way, the effects of the test procedure on the results are made evident and new possibilities for analysis of dielectric test results are open. Partial discharge and impulse test results are reported and analyzed following this approach.
Keywords :
Breakdown voltage; Dielectric liquids; Dielectrics and electrical insulation; Electric breakdown; Frequency; Impulse testing; Oil insulation; Partial discharges; Probability distribution; Stress;
fLanguage :
English
Journal_Title :
Electrical Insulation, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9367
Type :
jour
DOI :
10.1109/TEI.1985.348837
Filename :
4156768
Link To Document :