DocumentCode
783061
Title
Acoustic emission during DC operations of the ITER Central Solenoid model coil
Author
Arai, Kazuaki ; Ninomiya, Akira ; Ishigohka, Takeshi ; Takano, Katsutoshi ; Matsui, Kunihiro ; Michael, Philip C. ; Vieira, Rui F. ; Martovetsky, Nicholai N. ; Kaiho, Katsuyuki ; Nakajima, Hideo ; Takahashi, Yoshikazu ; Kato, Takashi ; Ando, Toshinari ; T
Author_Institution
Nat. Inst. of Adv. Ind. Sci. & Technol., Tsukuba, Japan
Volume
12
Issue
1
fYear
2002
fDate
3/1/2002 12:00:00 AM
Firstpage
504
Lastpage
507
Abstract
Acoustic emission (AE) signals from the Central Solenoid (CS) model coil developed in ITER program were studied during direct current (DC) operation. Estimation of the AE energy from the coil indicates close correlation between the AE energy and AC losses in the cable-in-conduit (CIC) conductor. This correlation comes from motions of the cables and dc-bonding of strands in the CIC conductors during repeated charging of the coil. The AE measurements clearly indicated the existence of mechanical disturbances even in the cases where the voltage spikes observed in the balance voltages were comparable to the noise level. In the case of the CS model coil, the locations of the mechanical disturbances could be determined using AE signals in combination with information from voltage spikes correlated with the AE signals.
Keywords
Tokamak devices; acoustic emission; fusion reactor design; superconducting magnets; Central Solenoid model coil; DC operation; ITER; acoustic emission; cable-in-conduit conductor; mechanical disturbances; voltage spikes; Acoustic emission; Acoustic testing; Cables; Coils; Conductors; Low pass filters; Magnetic field induced strain; Magnetic field measurement; Solenoids; Voltage;
fLanguage
English
Journal_Title
Applied Superconductivity, IEEE Transactions on
Publisher
ieee
ISSN
1051-8223
Type
jour
DOI
10.1109/TASC.2002.1018453
Filename
1018453
Link To Document