• DocumentCode
    783251
  • Title

    Studies on Noble Gas Scintillators

  • Author

    Henck, Mme R. ; Coche, A.

  • Author_Institution
    Centre de Recherches Nucleaires Departement de Chimie Nucleaire Strassbourg-Cronfnbourg (France)
  • Volume
    14
  • Issue
    1
  • fYear
    1967
  • Firstpage
    478
  • Lastpage
    486
  • Abstract
    The results from a study of the use of noble gases without wavelength shifters as scintillation detectors for nuclear particles are presented. The spectra and the time dependence of the fluorescence induced by ¿-particles in helium, neon, argon, krypton and xenon, have been investigated by single photoelectron techniques and are reported. A study of the scintillation efficiency as a function of gas pressure and of dimensions of the scintillation chamber, shows the great importance of geometrical factors in light collection. In all cases, experimental results on pulse heights and decay times would be reproduced within ± 5 % and the operation of these gas scin tillators as particle detectors was found to be satisfactory.
  • Keywords
    Atmosphere; Gases; Helium; Lead; Optical pulses; Pulse measurements; Radiation detectors; Scintillation counters; Solid scintillation detectors; Xenon;
  • fLanguage
    English
  • Journal_Title
    Nuclear Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9499
  • Type

    jour

  • DOI
    10.1109/TNS.1967.4324458
  • Filename
    4324458