• DocumentCode
    783439
  • Title

    Fault Location on Telephone Cables

  • Author

    Kantrowitz, Philip

  • Author_Institution
    Sonotone Corp., Elmsford, NY, USA
  • Volume
    6
  • Issue
    2
  • fYear
    1958
  • fDate
    12/1/1958 12:00:00 AM
  • Firstpage
    53
  • Lastpage
    57
  • Abstract
    An improved approach to fault location by pulse echo ranging on unloaded telephone cables is proposed, which requires a knowledge of the output unit step transient response of a matched cable. This has been obtained by numerical integration for 19 AWG nonloaded telephone quadded toll cable. Experimental results are given for unloaded spiral-four cable which has similar properties. The output unit step response is also given for an idealized semiinfinite loaded line for which the attenuation is approximately constant and the phase shift is proportional to frequency up to the cutoff radian frequency, Ωc. This result is used to demonstrate that the optimum rectangular pulse, T1, for echo ranging on loaded lines is given by T_{1} \\equiv 3.84/\\Omega _{c} .
  • Keywords
    Attenuation; Circuit faults; Communication cables; Cutoff frequency; Fault location; Impedance; Pulse generation; Telephony; Transient response; Voltage;
  • fLanguage
    English