DocumentCode
783439
Title
Fault Location on Telephone Cables
Author
Kantrowitz, Philip
Author_Institution
Sonotone Corp., Elmsford, NY, USA
Volume
6
Issue
2
fYear
1958
fDate
12/1/1958 12:00:00 AM
Firstpage
53
Lastpage
57
Abstract
An improved approach to fault location by pulse echo ranging on unloaded telephone cables is proposed, which requires a knowledge of the output unit step transient response of a matched cable. This has been obtained by numerical integration for 19 AWG nonloaded telephone quadded toll cable. Experimental results are given for unloaded spiral-four cable which has similar properties. The output unit step response is also given for an idealized semiinfinite loaded line for which the attenuation is approximately constant and the phase shift is proportional to frequency up to the cutoff radian frequency, Ωc . This result is used to demonstrate that the optimum rectangular pulse, T1 , for echo ranging on loaded lines is given by
.
.Keywords
Attenuation; Circuit faults; Communication cables; Cutoff frequency; Fault location; Impedance; Pulse generation; Telephony; Transient response; Voltage;
fLanguage
English
Journal_Title
Communications Systems, IRE Transactions on
Publisher
ieee
ISSN
0096-2244
Type
jour
DOI
10.1109/TCOM.1958.1097529
Filename
1097529
Link To Document