DocumentCode :
783578
Title :
R&D for a minigap undulator at LURE
Author :
Marcouillé, O. ; Boyer, J.-C. ; Corlier, M. ; Denise, S. ; Duval, J.-P. ; Herbeaux, C. ; Labrude, E. ; Lefèbvre, D. ; Marlats, J.-L. ; Rommeluère, P. ; Vandenberghe, M. ; Vétèran, J.
Volume :
12
Issue :
1
fYear :
2002
fDate :
3/1/2002 12:00:00 AM
Firstpage :
691
Lastpage :
694
Abstract :
An in-vacuum minipole (short period) Insertion Device has been developed at LURE (Laboratoire pour l´Utilization du Rayonnement Electromagnetique) in the frame of R&D. A particular attention has been especially taken in the design and the mechanics in order to ease the cancellation of magnetic errors which affect the performances of the ID. The magnetic field (0.68 T) is produced by two arrays of permanent magnets installed on a fixed gap frame. Each magnet can be vertically moved in order to correct multipolar errors and phase errors. In addition, end correctors have been especially designed to increase the efficiency of the multipolar correction. In this paper, the authors present the design of the undulator, the mechanical choices as well as the calculations and the vacuum tests.
Keywords :
permanent magnets; research initiatives; superconducting magnets; wigglers; 0.68 T; France; R&D; design; in-vacuum minipole insertion device; magnetic errors cancellation; magnetic field; mechanics; minigap undulator; multipolar correction; permanent magnets; vacuum tests; Error correction; Magnetic fields; Magnetic separation; Magnetization; Permanent magnets; Research and development; Steel; Structural beams; Superconducting magnets; Undulators;
fLanguage :
English
Journal_Title :
Applied Superconductivity, IEEE Transactions on
Publisher :
ieee
ISSN :
1051-8223
Type :
jour
DOI :
10.1109/TASC.2002.1018495
Filename :
1018495
Link To Document :