DocumentCode :
784330
Title :
The use of a permanent magnet for water content measurements of wood chips
Author :
Barale, P.J. ; Fong, C.G. ; Green, M.A. ; Luft, P.A. ; McInturff, A.D. ; Reimer, J.A. ; Yahnke, M.
Author_Institution :
Lawrence Berkeley Nat. Lab., CA, USA
Volume :
12
Issue :
1
fYear :
2002
fDate :
3/1/2002 12:00:00 AM
Firstpage :
975
Lastpage :
978
Abstract :
The Lawrence Berkeley National Laboratory has developed a device that measures the water content of wood chips, pulp and brown stock for the paper industry. This device employs a permanent magnet as the central part of a NMR measurement system. This report describes the magnet and the NMR measurement system. The results of water content measurements in wood chips in a magnetic field of 0.47 T are presented.
Keywords :
moisture measurement; nuclear magnetic resonance; paper industry; permanent magnets; wood processing; 0.47 T; NMR measurement system; RF coil; brown stock; magnet enclosure; moisture content measurements; paper industry; permanent magnet; pulp; water content measurements; wood chips; Magnetic field measurement; Magnetic separation; Moisture measurement; Nuclear magnetic resonance; Permanent magnets; Pulse measurements; Radio frequency; Semiconductor device measurement; Superconducting magnets; Water conservation;
fLanguage :
English
Journal_Title :