DocumentCode :
784421
Title :
Evaluation of reactive power meters in the presence of high harmonic distortion
Author :
Filipski, P.S. ; Labaj, P.W.
Author_Institution :
Nat. Res. Council of Canada, Ottawa, Ont., Canada
Volume :
7
Issue :
4
fYear :
1992
fDate :
10/1/1992 12:00:00 AM
Firstpage :
1793
Lastpage :
1799
Abstract :
Four reactive power meters, operating on different principles, were tested under nonsinusoidal conditions. Different definitions of the reactive power are discussed. Because the definition and meaning of the nonsinusoidal reactive power are still being actively debated, the readings of the tested meters were compared with four nonsinusoidal reactive powers and the first harmonic reactive power, to verify whether these readings can be interpreted as approximate measures of the different definitions. A digital instrument, programmed to measure each of these powers, was used as a reference
Keywords :
calibration; digital instrumentation; harmonics; power measurement; reactive power; digital instrument; high harmonic distortion; nonsinusoidal conditions; reactive power meters; Councils; Distortion measurement; Harmonic distortion; Instruments; Power system harmonics; Proposals; Reactive power; Strontium; System testing; Voltage;
fLanguage :
English
Journal_Title :
Power Delivery, IEEE Transactions on
Publisher :
ieee
ISSN :
0885-8977
Type :
jour
DOI :
10.1109/61.156980