• DocumentCode
    786527
  • Title

    The Pioneer Venus Orbiter Plasma Wave Investigation

  • Author

    Scarf, F.L. ; Taylor, W.W.L. ; Virobik, P.F.

  • Author_Institution
    TRW Defense and Space Systems, Redondo, CA 90278
  • Issue
    1
  • fYear
    1980
  • Firstpage
    36
  • Lastpage
    38
  • Abstract
    The Pioneer Venus plasma wave instrument has a selfcontained balanced electric dipole (effective length = 0.75 m) and a 4-channel spectrum analyzer (30-percent bandwidth filters with center frequencies at 100 Hz, 730 Hz, 5.4 kHz, and 30 kHz). The channels are continuously active and the highest Orbiter telemetry rate (2048 bps) yields 4 spectral scans/s. The total mass of 0.55 kg includes the electronics, the antenna, and the antenna deployment mechanism. This report contains a brief description of the instrument design and a discussion of the in-flight performance.
  • Keywords
    Dipole antennas; Frequency; Instruments; Ionosphere; Plasma measurements; Plasma waves; Sensor arrays; Space vehicles; Telemetry; Venus;
  • fLanguage
    English
  • Journal_Title
    Geoscience and Remote Sensing, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0196-2892
  • Type

    jour

  • DOI
    10.1109/TGRS.1980.350257
  • Filename
    4157130