DocumentCode
787042
Title
The Performance of a Counting-Mean-Square Voltage Channel in the EBR-II
Author
Popper, Glenn F. ; Harrer, Joseph M.
Author_Institution
Argonne National Laboratory Argonne, Illinois
Volume
15
Issue
1
fYear
1968
Firstpage
22
Lastpage
27
Abstract
A wide range neutron flux monitoring test channel based on counting and mean-square voltage techniques has been installed at the EBR-II. The measured responses to neutron flux are presented and compared to those predicted. Data taken while the reactor is on an essentially constant period during typical re-starts are shown. The gamma discrimination ratio for this system has been determined and is discussed.
Keywords
Detectors; Equations; Impedance; Inductors; Monitoring; Neutrons; Preamplifiers; Pulse circuits; System testing; Voltage;