DocumentCode :
787359
Title :
Satellite Instrumentation for Charged Particle Measurements III. Scintillation Spectrometer for Relativistic Electrons
Author :
Paolini, F.R. ; Theodoridis, G.C. ; Welsh, W.F.
Author_Institution :
American Science and Engineering Cambridge, Massachusetts
Volume :
15
Issue :
1
fYear :
1968
Firstpage :
200
Lastpage :
204
Abstract :
A scintillation spectrometer for OV1-13 is described. Scintillation pulses are accepted for differential analysis only if in coincidence with appropriate energy depositions within an associated dE/dx detector. This allows accurate measurement of electrons in the presence of high intensities of hard protons. The dE/dx detector and additional logic reduce spectrometer sensitivity by 80%, and broaden resolution to 50%. The geometrical factor is 1.0 × 10-2 cm2-ster.
Keywords :
Apertures; Electrons; Energy resolution; Instruments; Logic; Particle measurements; Protons; Satellites; Solid scintillation detectors; Spectroscopy;
fLanguage :
English
Journal_Title :
Nuclear Science, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9499
Type :
jour
DOI :
10.1109/TNS.1968.4324854
Filename :
4324854
Link To Document :
بازگشت