  • Abstract
    Solid state detectors, especially Ge(Li) drifted diodes, have given the biologist a new and powerful tool for determining the identity of radioactive species in biological samples. Often these samples contain very low quantities of radioactivity in a complex mixture of radionuclides. High resolution, maximum counting efficiency, suppression of background and Compton radiation and enhancement of photopeaks are required. A series of gamma-ray spectrometers has been developed to assay radionuclides in biological materials. These spectrometers have incorporated features that facilitate achieving these requirements. Samples up to 8.5 cm in diameter and 2.5 cm thick are now routinely analyzed. A range of gamma and x-ray energies from a few kilovolts to 2.5 Mev can be analyzed. Since the probability becomes rather high above 1 Mev that the favored gamma interaction within the Ge(Li) detector will be a Compton event with the resultant photoelectron interfering with the spectrum below the initial gamma-ray energy, it is necessary to suppress this type of interaction. This has been achieved by surrounding the Ge(Li) detectors with a scintillator for detecting scattered Compton photons. A method is described to enhance both anticoincidence and coincidence events. Both NaI(Tl) and plastic scintillators are used as anticoincidence shields. The optimum anticoincidence shield may not be a simple annulus. Some arguments and preliminary results are given to show the advantages of totally surrounding the Ge(Li) with a scintillator for 4 ¿ Compton suppression. The Compton shields vary from 9 inches in diameter for NaI(Tl) to 30 inches for plastic.
  • Keywords
    Biological materials; Diodes; Electromagnetic scattering; Event detection; Gamma ray detection; Gamma ray detectors; Particle scattering; Plastics; Solid state circuits; Spectroscopy;
  • fLanguage
    English
  • Journal_Title
    Nuclear Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9499
  • Type

    jour

  • DOI
    10.1109/TNS.1968.4324877
  • Filename
    4324877