DocumentCode
787904
Title
Calibration of sub-10-nm flying height using the bump response
Author
Zhang, J. ; Sheng, G.
Author_Institution
Data Storage Inst., Singapore, Singapore
Volume
39
Issue
5
fYear
2003
Firstpage
2474
Lastpage
2476
Abstract
This paper presents a study on the calibration of sub-10-nm fly height of slider by detecting slider response to laser bump with known height. The PZT sensor signal was applied to identify the slider air bearing resonance and slider body resonance. By comparing the signals from these two sources, improper measurement results due to the uncertainty of slider-bump response process can be eliminated. The time-frequency analysis of laser Doppler vibrometer measured slider bump responses also correlates the results.
Keywords
calibration; hard discs; height measurement; lead compounds; time-frequency analysis; vibration measurement; 10 nm; PZT; PZT sensor signal; PbZrO3TiO3; bump response; calibration; disk drive slider; flying height; laser Doppler vibrometer; laser bump; slider; slider air bearing resonance; slider body resonance; slider response; slider-bump response; time-frequency analysis; Calibration; Disk drives; Interference; Measurement errors; Optical films; Optical sensors; Resonance; Signal processing; System testing; Vibrometers;
fLanguage
English
Journal_Title
Magnetics, IEEE Transactions on
Publisher
ieee
ISSN
0018-9464
Type
jour
DOI
10.1109/TMAG.2003.816442
Filename
1233114