DocumentCode :
789492
Title :
On-board calibration system for millimeter-wave radiometers based on reference-polarized signal injection
Author :
Peverini, Oscar Antonio ; Tascone, Riccardo ; Carretti, Ettore ; Virone, Giuseppe ; Olivieri, Augusto ; Orta, Renato ; Cortiglioni, Stefano ; Monari, Jader
Author_Institution :
Inst. di Elettronica e di Ingegneria dell´´Informazione e delle Telecomunicazioni, Turin
Volume :
54
Issue :
1
fYear :
2006
Firstpage :
412
Lastpage :
420
Abstract :
This paper presents the architecture of a novel on-board calibration system for millimeter-wave radiometers aimed at measuring the Q,U Stokes parameters of the sky emission. This technique requires the injection of differently polarized reference signals, which is carried out by means of a specific component mounted in the antenna-feed system. The presented technique was developed by Cortiglioni et al. for the calibration of the Balloon-borne Radiometers for Sky Polarization Observations radiometers, specifically designed to measure the polarized sky emission by a correlation technique. A procedure for the accurate evaluation of the polarization state of the calibration signals is also reported. Numerical and experimental results are presented for the Ka-band calibrator in the operational conditions
Keywords :
calibration; radiometers; Ka band calibrator; Stokes parameters; antenna feed system; millimeter wave radiometers; onboard calibration system; reference polarized signal injection; sky emission; Antenna accessories; Antenna measurements; Calibration; Extraterrestrial measurements; Millimeter wave measurements; Millimeter wave technology; Polarization; Radiometers; Stokes parameters; Transducers; Calibration techniques; millimeter waves; radiometers; waveguide components;
fLanguage :
English
Journal_Title :
Microwave Theory and Techniques, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9480
Type :
jour
DOI :
10.1109/TMTT.2005.860496
Filename :
1573838
Link To Document :