DocumentCode
789684
Title
Poly-
Olefin Synthetic Oil: A New Paradigm in Repetitive High-Pressure Oil Switches
Author
Norgard, Peter ; Curry, Randy D. ; Sears, R.
Author_Institution
Dept. of Electr. & Comput. Eng., Missouri Univ.
Volume
34
Issue
5
fYear
2006
Firstpage
1662
Lastpage
1669
Abstract
A high-pressure oil switch for high-energy systems has been developed and tested to repetition rates up to 100 pps in burst mode and test voltages to -300 kV. The switch utilizes high-pressure flowing synthetic oil and advanced mechanical designs to achieve high-performance operation at pressures to 17.24 MPa (2500 psi). Experimental data is presented for both single-shot performance as well as continuous repetition rate performance to 20 pps. Electrode lifetime is evaluated for stainless steel and Elkonite to demonstrate electrode lifetime. Evidence is presented in support of the dependence of switching performance on the geometry of the switch
Keywords
electrodes; insulating oils; remaining life assessment; switchgear insulation; switchgear testing; -300 kV; 17.24 MPa; electrode lifetime evaluation; elkonite; high-pressure flowing synthetic oil; poly-alpha olefin synthetic oil; repetitive high-pressure oil switches; stainless steel; Absorption; Avalanche breakdown; Dielectric breakdown; Dielectric liquids; Electrodes; Petroleum; Steel; Switches; System testing; Voltage; High pressure; high-voltage switch; liquid dielectric; oil switch; rep-rate switch;
fLanguage
English
Journal_Title
Plasma Science, IEEE Transactions on
Publisher
ieee
ISSN
0093-3813
Type
jour
DOI
10.1109/TPS.2006.883340
Filename
1710024