DocumentCode
789846
Title
Influence of electrode area on the conditioning effect in vacuum
Author
Shioiri, T. ; Kamikawaji, T. ; Kaneko, E. ; Homma, M. ; Takahashi, H. ; Ohshima, I.
Author_Institution
Toshiba Corp., Tokyo, Japan
Volume
2
Issue
2
fYear
1995
fDate
4/1/1995 12:00:00 AM
Firstpage
317
Lastpage
320
Abstract
Using three types of copper electrodes with different surface areas, experiments were performed to investigate the influence of electrode area on the conditioning effect,which is a characteristic of dielectric breakdown in vacuum gaps. The conditioning process varied with electrode area: the smaller the electrode area, the sooner conditioning ended. Breakdown voltages after completion of conditioning also depended on electrode area: the smaller the electrode area, the higher the breakdown voltage
Keywords
copper; electric breakdown; electrodes; vacuum breakdown; vacuum insulation; Cu; Cu electrodes; breakdown voltage; conditioning effect; dielectric breakdown; electrode area; surface areas; vacuum gaps; vacuum interrupters; Breakdown voltage; Circuit testing; Copper; Current measurement; Dielectric breakdown; Dielectric materials; Electrodes; Surface treatment; Vacuum arcs; Vacuum breakdown;
fLanguage
English
Journal_Title
Dielectrics and Electrical Insulation, IEEE Transactions on
Publisher
ieee
ISSN
1070-9878
Type
jour
DOI
10.1109/94.388258
Filename
388258
Link To Document