DocumentCode :
790587
Title :
Design and Performance of the Sandia Laboratories Hermes II Flash X-Ray Generator
Author :
Martin, T.H.
Author_Institution :
Sandia Laboratories Albuquerque, New Mexico
Volume :
16
Issue :
3
fYear :
1969
fDate :
6/1/1969 12:00:00 AM
Firstpage :
59
Lastpage :
63
Abstract :
Pulsed power technology has grown rapidly during the last decade. Particular credit is due to research efforts at United Kingdom Atomic Weapons Research Establishment (AWRE). The largest machine presently in operation is the Sandia Laboratories Hermes II which has produced a 170 kA beam of electrons at energies of 12 million volts for times of 100 ns. This paper reviews the design and performance of the Hermes II and includes data from Hermes I, a prototype.
Keywords :
Capacitors; Electron beams; Electron tubes; Impedance; Laboratories; Oil insulation; Petroleum; Polyethylene; Stress; Voltage;
fLanguage :
English
Journal_Title :
Nuclear Science, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9499
Type :
jour
DOI :
10.1109/TNS.1969.4325178
Filename :
4325178
Link To Document :
بازگشت