DocumentCode
790821
Title
Correlation of Radiation With Electron and Neutron Signals Taken in a Plasma-Focus Device
Author
Kubes, Pavel ; Kravarik, Jozef ; Klir, Daniel ; Rezac, Karel ; Scholz, Marek ; Paduch, Marian ; Tomaszewski, Krzysztof ; Ivanova-Stanik, Irena ; Bienkowska, Barbara ; Karpinski, Leslaw ; Sadowski, Marek Jan ; Schmidt, Hellmut
Author_Institution
Czech Tech. Univ., Prague
Volume
34
Issue
5
fYear
2006
Firstpage
2349
Lastpage
2355
Abstract
In the PF 1000 plasma-focus device, deuterium is used as a filling gas for the study of fast neutrons (originated from D-D fusion reactions) and X-rays. The X-ray signals have two peaks. The first peak corresponds to the time of the minimum diameter of the pinch phase, as recorded by the visible frames. The second peak has its maximum 150 to 200 ns later. The electrons with energy above a few hundreds of kiloelectronvolts are registered mostly at the first peak in both axial directions. Upstream and downstream electrons differ in their intensity (ratio 3 : 1), temporal profile, and time of their maximum. The energy of the neutrons and the time of their generation are determined by the time-of-flight method using six or seven scintillation detectors positioned in the axial direction. Each neutron pulse has a dominant portion of beam-target origin with downstream energies up to 3.2 MeV and the final portion of the neutrons with energies in the range of 2.2 to 2.7 MeV. The evolution of the neutron pulses correlates with the visible frames. The first pulse correlates with the fast downstream motion of the intense radiating axis layer of the pinch and with the forming and existence of the radiating ball-shaped structure at the bottom of the dilating plasma sheath. The second neutron pulse correlates with the exploding of the plasma after the second pinching, and with the forming and existence of the structure of the dense plasma at the bottom of the dilating current sheath, which is similar to the first pulse
Keywords
deuterium; neutron sources; plasma X-ray sources; plasma diagnostics; plasma focus; plasma production; plasma sheaths; 2.2 to 2.7 MeV; D; PF 1000 plasma-focus device; X-ray signals; beam-target origin; dense plasma; deuterium-deuterium fusion reactions; dilating current sheath; dilating plasma sheath; downstream electrons; electron signals; fast neutrons; intense radiating axis layer; minimum-diameter pinch phase; neutron production; neutron signals; plasma diagnostics; radiating ball-shaped structure; scintillation detectors; temporal profile; time-of-flight method; upstream electrons; visible frames; Deuterium; Electrons; Neutrons; Plasma accelerators; Plasma density; Plasma devices; Plasma diagnostics; Plasma sheaths; Plasma x-ray sources; Production; Neutron production; X-ray radiation; plasma diagnostics; plasma focus (PF);
fLanguage
English
Journal_Title
Plasma Science, IEEE Transactions on
Publisher
ieee
ISSN
0093-3813
Type
jour
DOI
10.1109/TPS.2006.877629
Filename
1710124
Link To Document