DocumentCode :
791256
Title :
A study of ACSN comparison between spin-stand and magnetic force microscopy
Author :
Li, Shaoping ; Zhu, Wenzhong ; Palmer, Dean
Volume :
39
Issue :
5
fYear :
2003
Firstpage :
3438
Lastpage :
3440
Abstract :
Characterizing media noise and then improving media signal-to-noise ratio (SNR) are important issues for successfully implementing perpendicular recording technology. In this work, the measurements of the autocorrelation signal-to-noise (ACSN) have been conducted using both spin-stand testing and magnetic force microscopy (MFM) method. The ACSN was measured as a function of the linear density so as to analyze the media noise origins. The results obtained from two different methods show a good correlation if a saturation effect of the GMR read sensor is taken into consideration, indicating that the saturation process of GMR readers could actually improve the ACSN values at low linear density situations.
Keywords :
magnetic force microscopy; magnetic heads; magnetic recording noise; perpendicular magnetic recording; ACSN comparison; GMR read sensor; MFM; autocorrelation signal-to-noise; magnetic force microscopy; media noise; media signal-to-noise ratio; perpendicular recording; spin-stand testing; Autocorrelation; Density measurement; Force measurement; Magnetic force microscopy; Magnetic forces; Magnetic noise; Noise measurement; Perpendicular magnetic recording; Signal to noise ratio; Testing;
fLanguage :
English
Journal_Title :
Magnetics, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9464
Type :
jour
DOI :
10.1109/TMAG.2003.816175
Filename :
1233421
Link To Document :
بازگشت