DocumentCode :
792388
Title :
Development of an FPGA-Based Data Acquisition Module for Small Animal PET
Author :
Imrek, J. ; Novák, D. ; Hegyesi, Gy ; Kalinka, G. ; Molnár, J. ; Végh, J. ; Balkay, L. ; Emri, M. ; Molnár, G. ; Trón, L. ; Bagaméry, I. ; Bükki, T. ; Rózsa, S. ; Szabó, Zs ; Kerek, A.
Author_Institution :
Inst. of Nucl. Res., Hungarian Acad. of Sci., Debrecen
Volume :
53
Issue :
5
fYear :
2006
Firstpage :
2698
Lastpage :
2703
Abstract :
We report on the design of a data acquisition (DAQ) module for a small animal PET camera developed at our institutes. During the design an important guideline was to develop a system which is built up from strictly identical DAQ modules, and which has no built-in hardware limitation on the maximum number of modules. The developed DAQ module comprises of an LSO scintillator crystal block, a position sensitive PMT, analog signal conditioning circuits, a digitizer, an field programmable gate array (FPGA) for digital signal processing, and a communication module through which the collected data are sent to a cluster of computers for postprocessing and storage. Instead of implementing hardware coincidence detection between the modules, we attach a precise time stamp to each event in our design, and the coincidence is determined by the data collecting computers during postprocessing. The digital CFD algorithm implemented in the FPGA gives a time resolution of 2 ns FWHM for real detector signals
Keywords :
data acquisition; field programmable gate arrays; gamma-ray apparatus; gamma-ray detection; high energy physics instrumentation computing; medical image processing; position sensitive particle detectors; positron emission tomography; solid scintillation detectors; FPGA-based data acquisition module; LSO scintillator crystal block; analog signal conditioning circuits; communication module; digital constant fraction discriminator algorithm; digital signal processing; digitizer; field programmable gate array; image postprocessing; position sensitive PMT; small animal PET camera; time resolution; time stamp; Animals; Cameras; Circuits; Data acquisition; Field programmable analog arrays; Field programmable gate arrays; Guidelines; Hardware; Positron emission tomography; Signal processing; Data acquisition (DAQ); Ethernet; PET; digital CFD; small animal;
fLanguage :
English
Journal_Title :
Nuclear Science, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9499
Type :
jour
DOI :
10.1109/TNS.2006.876004
Filename :
1710258
Link To Document :
بازگشت