DocumentCode :
793497
Title :
Steady-State Analysis of a Two-Branch Resistance--Inductance Parallel Circuit Controlled by a Bidirectional ac Switch
Author :
Yair, Alexander
Author_Institution :
Faculty of Electrical Engineering, Technion¿Israel Institute of Technology, Haifa, Israel.
Issue :
2
fYear :
1976
fDate :
3/1/1976 12:00:00 AM
Firstpage :
138
Lastpage :
142
Abstract :
The currents and load voltage of a two-branch resistance-inductance parallel circuit controlled by an ac switch in series with the supply are derived. It is shown that the extinction angle is a transcendental function of the ratio of the absolute values of the load impedances, the load phase angles, and the triggering angle, but not (as claimed by another author) of the supply voltage.
Keywords :
Current supplies; Extinction coefficients; Impedance; Inductance; Semiconductor diodes; Steady-state; Switches; Switching circuits; Thyristors; Voltage control;
fLanguage :
English
Journal_Title :
Industry Applications, IEEE Transactions on
Publisher :
ieee
ISSN :
0093-9994
Type :
jour
DOI :
10.1109/TIA.1976.349393
Filename :
4157852
Link To Document :
بازگشت