• DocumentCode
    793775
  • Title

    Electrical characteristics of various contact contaminations

  • Author

    Neufeld, Christian N. ; Rieder, Werner F.

  • Author_Institution
    Inst. of Switching Devices & High Voltage, Univ. of Technol. Vienna, Austria
  • Volume
    18
  • Issue
    2
  • fYear
    1995
  • fDate
    6/1/1995 12:00:00 AM
  • Firstpage
    369
  • Lastpage
    374
  • Abstract
    Contact reliability may be endangered by various types of contact contaminations as particles, corrosion products, polymers or carbon deposits. Often information about the type of contamination may be gained by easily applicable measurements of current and contact voltage only: i.e., contact resistance measurements after each operation of a routine life test (employing increasing voltage and current), and voltage oscillograms across opening contacts
  • Keywords
    carbon; contact resistance; corrosion; electrical contacts; impurities; life testing; reliability; carbon deposits; contact contaminations; contact reliability; contact resistance measurements; corrosion products; electrical characteristics; life tests; particles; polymers; Contacts; Contamination; Corrosion; Current measurement; Electric variables; Electrical resistance measurement; Gain measurement; Pollution measurement; Polymers; Voltage;
  • fLanguage
    English
  • Journal_Title
    Components, Packaging, and Manufacturing Technology, Part A, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    1070-9886
  • Type

    jour

  • DOI
    10.1109/95.390318
  • Filename
    390318