Abstract :
Most hydrocarbon production using submersible pumps requires pumping of fluid that is 95% water or higher. Energy used to produce salt water is wasted, and disposal is expensive. Electricity costs are significant, and system efficiency is a major concern. In this application, induction motors (IMs) are less efficient than permanent-magnet motors (PMMs). Laboratory tests measured efficiency, power factor, kilowatts, current, and speed at various loads and frequencies. Field tests measured input power and flow using the same pump for both systems with negligible well drawdown. On average, the PMM used 20% less power than the IM.
Keywords :
induction motors; machine testing; permanent magnet motors; pumps; variable speed drives; PMM; electric submersible pumps; electricity costs; field tests; hydrocarbon production; induction motors; laboratory tests; permanent-magnet motors; salt water; Brushless motors; Induction motors; Permanent magnet motors; Rotors; Stator windings; Synchronous motors; Torque; Electric submersible pumps (ESPs); gas production; gas-well dewatering; oil-well ESPs; permanent-magnet motors (PMMs); water flood;
fLanguage :
English
Journal_Title :
Industry Applications, IEEE Transactions on
Publisher :
ieee
ISSN :
0093-9994
Type :
jour
DOI :
10.1109/TIA.2013.2288203
Filename :
6654310
Link To Document :
بازگشت