DocumentCode
795151
Title
Effect of supply voltage frequency on testing of insulation system
Author
Hauschild, W. ; Cavallini, Andrea ; Montanari, Gian
Volume
13
Issue
5
fYear
2006
Firstpage
1189
Lastpage
1191
Abstract
This paper investigates a subject of high practical importance and proposes representative frequency range definition for HVAC testing with PD measurement which can improve both, on-site and laboratory testing. It will also strengthen the clear connection between stresses in service and HVAC testing. Furthermore it creates the correspondence between on-line PD monitoring and off-line PD testing
Keywords
insulation testing; monitoring; partial discharge measurement; HVAC testing; PD measurement; PD monitoring; insulation system; laboratory testing; stresses; supply voltage frequency effect; Electric breakdown; Frequency; Geographic Information Systems; Insulation testing; Low voltage; Partial discharges; Physics; Power cables; Stress; System testing;
fLanguage
English
Journal_Title
Dielectrics and Electrical Insulation, IEEE Transactions on
Publisher
ieee
ISSN
1070-9878
Type
jour
DOI
10.1109/TDEI.2006.247849
Filename
1714947