DocumentCode :
795218
Title :
Silicon Radiation Detector Monitors Nitrogen 16 in a Power Reactor
Author :
Mallory, P.G.
Author_Institution :
Canadian General Electric Co. Ltd. Peterborough Ontario Canada
Volume :
17
Issue :
1
fYear :
1970
Firstpage :
520
Lastpage :
523
Abstract :
A totally depleted diffused junction silicon radiation detector is used to monitor N16 in the coolant of a heavy water nuclear power reactor. The detector operates at boiler room ambient temperature and is stable and reliable. The system provides discrimination against background from corrosion and activation products with very little shielding required. The detector characteristics which affect accuracy are described and special features are incorporated to improve system stability.
Keywords :
Boilers; Coolants; Inductors; Lithium; Monitoring; Neutrons; Nitrogen; Silicon radiation detectors; Temperature; Voltage;
fLanguage :
English
Journal_Title :
Nuclear Science, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9499
Type :
jour
DOI :
10.1109/TNS.1970.4325624
Filename :
4325624
Link To Document :