• DocumentCode
    796054
  • Title

    Performance of CdTe as a Gamma Spectrometer and Detector

  • Author

    Zanio, K. ; Neeland, J. ; Montano, H.

  • Author_Institution
    Hughes Research Laboratories Malibu, California
  • Volume
    17
  • Issue
    3
  • fYear
    1970
  • fDate
    6/1/1970 12:00:00 AM
  • Firstpage
    287
  • Lastpage
    295
  • Abstract
    The gamma response of CdTe surface barrier detectors fabricated from semi-insulating material is analyzed. Small devices (10 mm3 to 15 mm3) from vapor grown crystals are capable at room temperature of resolving photopeaks at 90% charge collection efficiency for gamma emitters ranging in energy from 122 keV for 57Co to 1.33 MeV for 60Co. A resolution of 16% (FWHM) has been obtained with 137Cs (662 keV). Incomplete charge collection due to heavy trapping degrades resolution and limits the size of present devices. Larger devices (¿l cm3) prepared from melt crystals, although quite efficient to gammas (80% to 60Co), cannot resolve photopeaks. Their performance for straight counting applications is limited by a temperature dependent count rate, polarization at low temperatures and thermal noise at high temperatures. Detrapping of electrons and holes is necessary to prevent polarization at low temperatures and may be useful in extending the high temperature limit.
  • Keywords
    Crystals; Energy resolution; Gamma ray detection; Gamma ray detectors; Polarization; Response surface methodology; Semiconductor materials; Spectroscopy; Temperature dependence; Temperature distribution;
  • fLanguage
    English
  • Journal_Title
    Nuclear Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9499
  • Type

    jour

  • DOI
    10.1109/TNS.1970.4325702
  • Filename
    4325702