DocumentCode :
796439
Title :
Arc Suppression of a DC Energized Contactor under Inductive Load
Author :
Passey, Douglas A. ; Chen, Chun F.
Author_Institution :
Hewlett Packard, Lake Stevens Instrument Division, 8600 Soper Hill Road, Everett, WA 98205-1298.
Issue :
6
fYear :
1985
Firstpage :
1354
Lastpage :
1358
Abstract :
Arc suppression of a dc energized contactor is presented. A circuit is developed to operate the contactor at zero voltage crossing for contact closure and at zero current crossing for contact opening under inductive load. A self-learning feature of contactor characteristics is also provided in the circuit such that the device can be adaptable to any dc energized contactor without discrimination.
Keywords :
Circuits; Coils; Contacts; Electromagnetic interference; Frequency conversion; Inductors; Industry Applications Society; Switches; Timing; Voltage;