DocumentCode :
796929
Title :
A model of gastric electrical activity in health and disease
Author :
Familoni, Babajide O. ; Abell, Thomas L. ; Bowes, Kenneth L.
Author_Institution :
Dept. of Electr. Eng., Memphis Univ., TN, USA
Volume :
42
Issue :
7
fYear :
1995
fDate :
7/1/1995 12:00:00 AM
Firstpage :
647
Lastpage :
657
Abstract :
The idea of diagnosing gastric dysfunction from noninvasive measurements of gastric electrical activity (GEA) is intuitively appealing, but the predictive accuracy of the cutaneous signal, especially that of its amplitude, is still in question. Mathematical modeling provides a means of investigating, analyzing, and predicting GEA measured percutaneously. In this study, a model of GEA applicable both in health and disease was developed and simulated for a cylindrical body surface. Body-surface maps of the simulated electrogastrogram (EGG) were generated at a 20 by 20 array of sites on the model\´s surface, and the accuracy of the percutaneous method in detecting simulated gastric electrical abnormalities was determined. The relationship between the amplitude of the simulated surface EGG and the velocity of propagation of the myogenic activity was also investigated. This was compared to a similar investigation of the fluctuations in the amplitude of the surface EGG with the velocity of propagation of the serosal activity measured in humans. The diagnostic accuracy of the measured cutaneous EGG in humans was also determined. The results obtained from the mathematical model show that the amplitude of the electrogastrogram increases with the propagation velocity of GEA. Similar results were obtained from the experimental measurements. The amplitude of the simulated and measured cutaneous signal correlated well (p<0.05) with the phase shift of the simulated and measured activities, (-0.85, -0.54), respectively, Serosal normal activity, tachygastria, and uncoupling mere detected 67%, 90%, and 0% of the time, respectively, at the cutaneous electrode in humans, In simulations, normal activity and tachygastria were accurately detected at all 100 sites on the surface, Uncoupling simulated with 50% of the myogenic sources "diseased" was detected at only 20 of the 400 sites. The results confirm that the amplitude of the cutaneous signal is a function of the velocity of propagati- - on of the myogenic signal. It also confirms that while GEA in health may be accurately predicted from percutaneous recordings, frequency and phase/coupling abnormalities are poorly detected from single-channel electrogastrograms. This suggests the use of multiple-channel surface recordings in clinical electrogastrography.
Keywords :
bioelectric phenomena; patient diagnosis; physiological models; body-surface maps; clinical electrogastrography; cutaneous signal; cylindrical body surface; gastric dysfunction diagnosis; gastric electrical activity model; mathematical modeling; multiple-channel surface recordings; myogenic signal; myogenic sources; noninvasive measurements; percutaneous recordings; phase/coupling abnormalities; propagation velocity; simulated electrogastrogram; Accuracy; Biological system modeling; Diseases; Fluctuations; Humans; Mathematical model; Noninvasive treatment; Phase detection; Phase measurement; Time measurement; Body Surface Potential Mapping; Computer Simulation; Humans; Models, Biological; Signal Processing, Computer-Assisted; Stomach; Stomach Diseases;
fLanguage :
English
Journal_Title :
Biomedical Engineering, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9294
Type :
jour
DOI :
10.1109/10.391163
Filename :
391163
Link To Document :
بازگشت