DocumentCode :
797692
Title :
Performance of Large Germanium Detectors at Elevated Temperatures for Satellite Applications
Author :
Nakano, G.H. ; Imhof, W.L.
Author_Institution :
Lockheed Palo Alto Research Laboratory Lockheed Missiles & Space Company 3251 Hanover Street, Palo Alto, California 94304 (415) 324-3311, Ext. 45115
Volume :
18
Issue :
1
fYear :
1971
Firstpage :
258
Lastpage :
263
Abstract :
A measurement program has been undertaken to investigate design criteria for satellite-borne Ge(Li) detector systems. The resolution, pulse height, reverse current and efficiency have been measured as a function of temperature and bias voltage for large Ge(Li) detectors. For space applications the important parameters are the knees (rapid changes) in the resolution and leakage current versus temperature. These features are observed to vary appreciably from detector to detector.
Keywords :
Coolants; Copper; Detectors; Fingers; Gamma ray detection; Germanium; Pulse amplifiers; Satellites; Temperature; Voltage;