DocumentCode :
797908
Title :
Eddy-Current Probe-Type Sodium Flowsensor for FFTF Reactor Fuel Channel Flow Monitoring
Author :
Brewer, John ; Jaross, Robert A. ; Brown, Russell L.
Author_Institution :
Argonne National Laboratory Argonne, Illinois
Volume :
18
Issue :
1
fYear :
1971
Firstpage :
372
Lastpage :
377
Abstract :
An eddy-current probe-type flowsensor is being developed for the FFTF to indicate sodium flow velocity at the outlet of a fuel channel in a temperature range of 300??F to 1200??F and a velocity range of 0-18 fps. Design considerations, out-of-reactor tests, both dry and in sodium, were performed and results are presented. Typical sensitivity of 0.6 mV rms/ft-sec has been obtained with excellent stability.
Keywords :
Coils; Crosstalk; Fuels; Inductors; Laboratories; Monitoring; Probes; Stability; Temperature distribution; Temperature sensors;
fLanguage :
English
Journal_Title :
Nuclear Science, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9499
Type :
jour
DOI :
10.1109/TNS.1971.4325894
Filename :
4325894
Link To Document :
بازگشت