Title : 
Neutron Sensitive Criticality Detection System
         
        
            Author : 
Friend, P.C. ; Ratcliffe, C.A.
         
        
            Author_Institution : 
Battelle Memorial Institute Pacific Northwest Laboratories Richland, Washington 99352
         
        
        
        
        
        
        
            Abstract : 
An improved alarm system to detect and warn against uncontrolled nuclear criticality events has been developed for the Hanford site. The system is neutron sensitive with an alarm threshold of 8 millirad/hour of "steady" neutron irradiation or 4 microrad of pulsed radiation. Redundancy techniques and self-check features have been incorporated whenever possible to enhance operational reliability.
         
        
            Keywords : 
Alarm systems; Buildings; Circuit noise; Detectors; Event detection; Neutrons; Pulse amplifiers; Pulse circuits; Relays; Thyristors;
         
        
        
            Journal_Title : 
Nuclear Science, IEEE Transactions on
         
        
        
        
        
            DOI : 