• DocumentCode
    797911
  • Title

    Neutron Sensitive Criticality Detection System

  • Author

    Friend, P.C. ; Ratcliffe, C.A.

  • Author_Institution
    Battelle Memorial Institute Pacific Northwest Laboratories Richland, Washington 99352
  • Volume
    18
  • Issue
    1
  • fYear
    1971
  • Firstpage
    378
  • Lastpage
    379
  • Abstract
    An improved alarm system to detect and warn against uncontrolled nuclear criticality events has been developed for the Hanford site. The system is neutron sensitive with an alarm threshold of 8 millirad/hour of "steady" neutron irradiation or 4 microrad of pulsed radiation. Redundancy techniques and self-check features have been incorporated whenever possible to enhance operational reliability.
  • Keywords
    Alarm systems; Buildings; Circuit noise; Detectors; Event detection; Neutrons; Pulse amplifiers; Pulse circuits; Relays; Thyristors;
  • fLanguage
    English
  • Journal_Title
    Nuclear Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9499
  • Type

    jour

  • DOI
    10.1109/TNS.1971.4325895
  • Filename
    4325895