Precision of Shutdown Margin Measurements Using the Two-Frequency Reactor Noise Technique in an LMFBR
Author :
Buhl, A.R. ; Ackermann, N.J., Jr.
Author_Institution :
Oak Ridge National Laboratory Oak Ridge, Tennessee 37830
Volume :
18
Issue :
1
fYear :
1971
Firstpage :
430
Lastpage :
434
Abstract :
The precision of reactor noise techniques for measuring subcritical reactivity can be related to detector efficiency and parameters of the measuring instrumentation. Using a two-detector cross-correlation technique, we have determined that such measurements can be made in a certain fast reactor (the FFTF) to -3 to -5 dollars with acceptable statistics and measurement times.
Keywords :
Detectors; Frequency; Inductors; Measurement standards; Neutrons; Noise measurement; Reactor instrumentation; Signal analysis; Signal detection; Standards development;