DocumentCode
798120
Title
Setting Test Intervals and Allowable Bypass Times as a Function of Protection System Goals
Author
Hirsch, Herbert M.
Author_Institution
General Electric Company San Jose, California
Volume
18
Issue
1
fYear
1971
Firstpage
488
Lastpage
494
Abstract
This analysis demonstrates the usefulness of availability design goals for determining required periodic test intervals and allowable bypass times as permitted by IEEE-279 criteria. Formulas are developed for calculating these times for instrumentation logic configurations common to reactor protection systems. Both simultaneous and uniformly staggered test schedules are considered. In addition to sample problems illustrating the application of these formulas, nomographs are presented for rapid graphical determination of test intervals and bypass times.
Keywords
Availability; Calibration; Inductors; Logic testing; Nuclear power generation; Power system protection; Reactor instrumentation; Safety; Sections; System testing;
fLanguage
English
Journal_Title
Nuclear Science, IEEE Transactions on
Publisher
ieee
ISSN
0018-9499
Type
jour
DOI
10.1109/TNS.1971.4325914
Filename
4325914
Link To Document