• DocumentCode
    799440
  • Title

    Beam Matching Problems concerning the Axial Injection System for the Karlsruhe Cyclotron

  • Author

    Lütter, W.P. ; Schild, F. ; Thimmel, H.M. ; Wucherer, P.

  • Author_Institution
    Allgemeine Elektricitÿts-Gesellschaft AEG-Telefunken, Frankfurt/Main, Germany
  • Volume
    18
  • Issue
    3
  • fYear
    1971
  • fDate
    6/1/1971 12:00:00 AM
  • Firstpage
    321
  • Lastpage
    325
  • Abstract
    The Karlsruhe cyclotron is in operation since 1963. In the meantime, a polarized deuteron source has been developed by a group of GFK Karlsruhe. To operate the cyclotron with polarized ions an axial injection system has been ordered at AEG, associated with the construction of a new RF-system. During a shut-down period of three months the complete new system will be taken in operation in this summer. The system has to operate with an external source as well as with an internal source. The central region and the axial beam line have been calculated to have a full transmittance for a phase space area of 500 mm mrad in both directions and a phase width of 30° (related to the RF) in the 3¿-mode.
  • Keywords
    Acceleration; Cyclotrons; Geometrical optics; Geometry; Optical beams; Orbital calculations; Particle beams; Polarization; Radio frequency; Structural beams;
  • fLanguage
    English
  • Journal_Title
    Nuclear Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9499
  • Type

    jour

  • DOI
    10.1109/TNS.1971.4326041
  • Filename
    4326041