• DocumentCode
    799779
  • Title

    Start up performance of load-commutated inverter fed synchronous machine drives

  • Author

    Sudhoff, S.D. ; Zivi, E.L. ; Collins, T.D.

  • Author_Institution
    Dept. of Electr. Eng., Missouri Univ., Rolla, MO, USA
  • Volume
    10
  • Issue
    2
  • fYear
    1995
  • fDate
    6/1/1995 12:00:00 AM
  • Firstpage
    268
  • Lastpage
    274
  • Abstract
    Load-commutated inverter (LCI) synchronous machine drives are common in the high power range. However, the starting performance of these systems is a concern since load-commutation cannot occur at arbitrarily low speeds. This paper compares three different starting strategies including one apparently neglected method-normal load commutation. In particular, it is shown that, depending on system parameters, it may be possible to start the system with no special provision for start up. A method to determine whether a given system can be started using load commutation is presented
  • Keywords
    commutation; invertors; load (electric); machine testing; machine theory; starting; synchronous motor drives; load-commutated inverter; normal load commutation; start-up performance; starting strategies; synchronous machine drives; system parameters; Circuits; Commutation; Genetic mutations; Inverters; Marine vehicles; Power systems; Rotors; Stators; Synchronous machines; Synchronous motors;
  • fLanguage
    English
  • Journal_Title
    Energy Conversion, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0885-8969
  • Type

    jour

  • DOI
    10.1109/60.391892
  • Filename