Abstract
Load-commutated inverter (LCI) synchronous machine drives are common in the high power range. However, the starting performance of these systems is a concern since load-commutation cannot occur at arbitrarily low speeds. This paper compares three different starting strategies including one apparently neglected method-normal load commutation. In particular, it is shown that, depending on system parameters, it may be possible to start the system with no special provision for start up. A method to determine whether a given system can be started using load commutation is presented
Keywords
commutation; invertors; load (electric); machine testing; machine theory; starting; synchronous motor drives; load-commutated inverter; normal load commutation; start-up performance; starting strategies; synchronous machine drives; system parameters; Circuits; Commutation; Genetic mutations; Inverters; Marine vehicles; Power systems; Rotors; Stators; Synchronous machines; Synchronous motors;