DocumentCode :
800214
Title :
Sparking Measurements in a Single Gap Cavity
Author :
Böhne, D. ; Karger, W. ; Miersch, E. ; Ròske, W. ; Stadler, B.
Author_Institution :
Gesellschaft fÿr Schwerionenforschung, Darmstadt, Germany UNILAC - Group
Volume :
18
Issue :
3
fYear :
1971
fDate :
6/1/1971 12:00:00 AM
Firstpage :
568
Lastpage :
571
Abstract :
At first, a review of more general breakdown studies, performed in a specially designed sparking cavity, is presented. Then the long term performance of two prototype cavities is described. Spark rate and x-ray level are reported versus gap gradient, electrode material and conditioning procedure. Mean gap fields up to 25 MV/m have been obtained. It turned out that copper electrodes show the tendency to severe deconditioning developments while the x-ray level for aluminium electrodes remained stable.
Keywords :
Aluminum; Electric breakdown; Electrodes; Geometry; Prototypes; Pumps; Sparks; Surface cleaning; Surface contamination; Vacuum systems;
fLanguage :
English
Journal_Title :
Nuclear Science, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9499
Type :
jour
DOI :
10.1109/TNS.1971.4326117
Filename :
4326117
Link To Document :