DocumentCode :
801733
Title :
Measurement of the Titanium Vacuum Chamber Eddy Current Fields and Pole Face Winding Corrections for the Zero Gradient Synchrotron (ZGS)
Author :
Crosbie, E. ; Khoe, T. ; Berrill, E. ; Hardek, T. ; George, R.
Author_Institution :
Argonne National Laboratory Argonne, Illinois
Volume :
18
Issue :
3
fYear :
1971
fDate :
6/1/1971 12:00:00 AM
Firstpage :
1000
Lastpage :
1001
Abstract :
The titanium vacuum chambers (TVC) which will be installed in the ZGS are equipped with pole face windings for correction of the eddy current fields. A prototype of the chamber and correction windings has been installed in a spare magnet block test fixture for measurement of the eddy current fields as a function of radial position and time. The ten difference signals from 20 test coils are read into a SEL-810A computer. The computer displays the measured gradient on a scope, either as a function of radial position at a selected time during the magnet pulse or as a function of time at a selected position. Thus, the result of applying compensating pulses to the pole face windings can be shown directly.
Keywords :
Current measurement; Eddy currents; Magnetic field measurement; Poles and zeros; Position measurement; Prototypes; Pulse measurements; Synchrotrons; Time measurement; Titanium;