Title : 
Measurement of the Titanium Vacuum Chamber Eddy Current Fields and Pole Face Winding Corrections for the Zero Gradient Synchrotron (ZGS)
         
        
            Author : 
Crosbie, E. ; Khoe, T. ; Berrill, E. ; Hardek, T. ; George, R.
         
        
            Author_Institution : 
Argonne National Laboratory Argonne, Illinois
         
        
        
        
        
            fDate : 
6/1/1971 12:00:00 AM
         
        
        
        
            Abstract : 
The titanium vacuum chambers (TVC) which will be installed in the ZGS are equipped with pole face windings for correction of the eddy current fields. A prototype of the chamber and correction windings has been installed in a spare magnet block test fixture for measurement of the eddy current fields as a function of radial position and time. The ten difference signals from 20 test coils are read into a SEL-810A computer. The computer displays the measured gradient on a scope, either as a function of radial position at a selected time during the magnet pulse or as a function of time at a selected position. Thus, the result of applying compensating pulses to the pole face windings can be shown directly.
         
        
            Keywords : 
Current measurement; Eddy currents; Magnetic field measurement; Poles and zeros; Position measurement; Prototypes; Pulse measurements; Synchrotrons; Time measurement; Titanium;
         
        
        
            Journal_Title : 
Nuclear Science, IEEE Transactions on
         
        
        
        
        
            DOI : 
10.1109/TNS.1971.4326260