DocumentCode :
802112
Title :
A Study of CT for Radio-Frequency Currents Using Complex Permeability
Author :
Fujiwara, T. ; Tahara, R.
Author_Institution :
Matsushita Electric Works, Ltd.
Volume :
8
Issue :
3
fYear :
1993
fDate :
3/1/1993 12:00:00 AM
Firstpage :
138
Lastpage :
143
Abstract :
This paper describes an analysis of the characteristics of current transformers (CTs), taking the dynamic hysteresis loops of the magnetic core into consideration. The analysis is performed using a complex permeability to represent the magnetic hysteresis. This method is applied to CTs with radio-frequency currents for switching power supplies, and the calculated results are in very good agreement with experiment. This analytical method, which may be used to calculate the ratio of transformation and the CT phase angle, is useful in designing CTs.
Keywords :
Circuit faults; Computed tomography; Current measurement; Current transformers; Magnetic analysis; Magnetic cores; Magnetic hysteresis; Permeability; Radio frequency; Transformer cores;
fLanguage :
English
Journal_Title :
Magnetics in Japan, IEEE Translation Journal on
Publisher :
ieee
ISSN :
0882-4959
Type :
jour
DOI :
10.1109/TJMJ.1993.4565593
Filename :
4565593
Link To Document :
بازگشت