DocumentCode :
804642
Title :
Diffraction tomographic imaging with a circular array
Author :
Naidu, Prabhakar S. ; Vasuki, A. ; Satyamurthy, P. ; Anand, L.
Author_Institution :
Dept. of Electr. Commun. Eng., Indian Inst. of Sci., Bangalore, India
Volume :
42
Issue :
4
fYear :
1995
fDate :
7/1/1995 12:00:00 AM
Firstpage :
787
Lastpage :
789
Abstract :
A new approach of imaging an object profile from the scattered wavefield, which is measured using a large (far field approximation) circular array of sensors surrounding the object, is described. It is shown that the measured field is itself proportional to the Fourier transform of the object. Consequently, as compared to the existing methods, such as back propagation method for a linear array, our method overcomes the well known effects of the finite window in numerical evaluation of the Fourier transform of the measured scattered field. This results into improved reconstruction.<>
Keywords :
Fourier transforms; acoustic tomography; image reconstruction; ultrasonic diffraction; ultrasonic imaging; Fourier transform; circular array; diffraction tomographic imaging; far field approximation; image reconstruction; object profile; scattered wavefield; Acoustic diffraction; Acoustic scattering; Fourier transforms; Microwave imaging; Sea measurements; Sensor arrays; Shape measurement; Tomography; Ultrasonic imaging; Ultrasonic variables measurement;