• DocumentCode
    805133
  • Title

    Control Rod Signal Multiplexing

  • Author

    Minor, G.C. ; Moore, S.E.

  • Author_Institution
    General Electric Company Nuclear Power Generation Control Department San Jose, California
  • Volume
    19
  • Issue
    1
  • fYear
    1972
  • Firstpage
    789
  • Lastpage
    792
  • Abstract
    This paper describes an application of multiplexing and system self-testing to the rod control and status-monitoring system of a Boiling Water Reactor (BWR). The approach uses modularity at the field sensors with minimum interconnecting cables to the control room. The coding of the signal words employs error-detecting techniques to improve system reliability and availability. Fault diagnostics and identification improve the maintainability of the system.
  • Keywords
    Availability; Built-in self-test; Cables; Circuits; Conductors; Control systems; Costs; Inductors; Nuclear power generation; Wire;
  • fLanguage
    English
  • Journal_Title
    Nuclear Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9499
  • Type

    jour

  • DOI
    10.1109/TNS.1972.4326596
  • Filename
    4326596