  • Abstract
    The relationship between steady state error and system type is presented in terms of the classical solution of ordinary differential equations. The addition of integrators in the forward path to obtain zero steady state error is described in terms of changes in the structure of the closed loop differential equation. Ordinary differential equation structural characteristics which yield zero steady state error for constant, ramp and parabolic inputs are summarized.