• DocumentCode
    807855
  • Title

    Nonlinearity characterisation of microwave detectors for radiometer applications

  • Author

    Närhi, T.

  • Author_Institution
    RF Syst. Div., Eur. Space Res. & Technol. Centre, Noordwijk, Netherlands
  • Volume
    32
  • Issue
    3
  • fYear
    1996
  • fDate
    2/1/1996 12:00:00 AM
  • Firstpage
    224
  • Lastpage
    225
  • Abstract
    The accuracy of microwave radiometers is affected by the deviation of the detector from the ideal square-law behaviour. A method is presented for determining the error caused by higher order nonlinearities, based on the experimental characterisation of the nonlinearities with a two-tone test. In actual operation with Gaussian noise as the input signal, the error caused by higher order nonlinearities is found to be greater than that with sinusoidal input signal
  • Keywords
    error analysis; measurement errors; microwave detectors; radiometers; Gaussian noise input signal; experimental characterisation; higher order nonlinearities; ideal square-law behaviour deviation; microwave detectors; microwave radiometers; nonlinearity characterisation; radiometer applications; two-tone test;
  • fLanguage
    English
  • Journal_Title
    Electronics Letters
  • Publisher
    iet
  • ISSN
    0013-5194
  • Type

    jour

  • DOI
    10.1049/el:19960109
  • Filename
    490815