DocumentCode :
809609
Title :
Analysis of AC losses in HTS pancake windings for transformer according to the operating temperature
Author :
Kim, Jong-Tae ; Kim, Woo-Seok ; Kim, Sung-Hoon ; Choi, Kyeong-Dal ; Han, Jin-Ho ; Hong, Gye-Won ; Hahn, Song-Yop
Author_Institution :
Graduate Sch. of Energy, Korea Polytech. Univ., Kyonggi-do, South Korea
Volume :
41
Issue :
5
fYear :
2005
fDate :
5/1/2005 12:00:00 AM
Firstpage :
1888
Lastpage :
1891
Abstract :
AC loss is one of the most important parameters in high-temperature superconducting (HTS) ac devices. Among the HTS ac power devices, the transformer is the essential part in the electrical power system. But unfortunately, the transformer is the worst device concerning ac loss because of very large magnetization loss due to high magnetic field applied to the HTS wire. We calculated the magnetization losses in HTS pancake windings for transformer according to the operating temperature. Two kinds of arrangements of HTS pancake windings were adopted for calculation of ac loss of shell-type transformer, and the analysis results were presented and discussed.
Keywords :
high-temperature superconductors; magnetic leakage; magnetisation; windings; AC losses analysis; HTS pancake windings; HTS transformer; electrical power system; high-temperature superconducting; magnetization losses; operating temperature; shell-type transformer; Critical current; High temperature superconductors; Magnetic analysis; Magnetic fields; Magnetic losses; Magnetization; Power transformer insulation; Shape; Superconducting filaments and wires; Temperature dependence; AC loss; HTS transformer; operating temperature; pancake winding;
fLanguage :
English
Journal_Title :
Magnetics, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9464
Type :
jour
DOI :
10.1109/TMAG.2005.846277
Filename :
1430991
Link To Document :
بازگشت