Title :
3 GHz Superconducting Accelerator Cavity for Use in an Electron Synchrotron
Author :
Sundelin, R. ; von Borstel, E. ; Kirchgessner, J. ; Rice, D. ; Tigner, M.
Author_Institution :
Laboratory of Nuclear Studies Cornell University Ithaca, New York 14850
fDate :
6/1/1973 12:00:00 AM
Abstract :
Experience has shown that superconducting accelerator cavity performance improves as the operating frequency rises. To use this effect to advantage in an electron synchrotron one must develop cavities of aperture large enough to provide the necessary phase space admittance and of such a configuration as to avoid problems with lost particles and synchrotron radiation in the orbit plane. The development of such a cavity, open in the mid-plane, is described and test results given.
Keywords :
Acceleration; Copper; Electron accelerators; Electron beams; Foot; Laboratories; Particle accelerators; Radio frequency; Superconducting magnets; Synchrotron radiation;
Journal_Title :
Nuclear Science, IEEE Transactions on
DOI :
10.1109/TNS.1973.4327052