• DocumentCode
    809984
  • Title

    Two-port network analyzer calibration using an unknown ´thru´

  • Author

    Ferrero, Andrea ; Pisani, Umberto

  • Author_Institution
    Dipartimento di Elettronica, Politecnico di Torino, Italy
  • Volume
    2
  • Issue
    12
  • fYear
    1992
  • Firstpage
    505
  • Lastpage
    507
  • Abstract
    A procedure performed by using a genuine two-port reciprocal network instead of a standard ´thru´ in a full two-port error correction of an automatic network analyzer is presented. Although it can be applied to any type of waveguide system, the proposed technique is particularly useful with noninsertable coaxial or one-wafer devices. Experimental comparisons show that the suggested procedure provides a great degree of accuracy.<>
  • Keywords
    S-matrix theory; S-parameters; calibration; error correction; microwave measurement; network analysers; automatic network analyzer; calibration; one-wafer devices; two-port error correction; two-port reciprocal network; waveguide system; Calibration; Coaxial components; Connectors; Error correction; Measurement standards; Performance analysis; Scattering parameters; Testing; Transmission line matrix methods; Waveguide components;
  • fLanguage
    English
  • Journal_Title
    Microwave and Guided Wave Letters, IEEE
  • Publisher
    ieee
  • ISSN
    1051-8207
  • Type

    jour

  • DOI
    10.1109/75.173410
  • Filename
    173410