DocumentCode
809984
Title
Two-port network analyzer calibration using an unknown ´thru´
Author
Ferrero, Andrea ; Pisani, Umberto
Author_Institution
Dipartimento di Elettronica, Politecnico di Torino, Italy
Volume
2
Issue
12
fYear
1992
Firstpage
505
Lastpage
507
Abstract
A procedure performed by using a genuine two-port reciprocal network instead of a standard ´thru´ in a full two-port error correction of an automatic network analyzer is presented. Although it can be applied to any type of waveguide system, the proposed technique is particularly useful with noninsertable coaxial or one-wafer devices. Experimental comparisons show that the suggested procedure provides a great degree of accuracy.<>
Keywords
S-matrix theory; S-parameters; calibration; error correction; microwave measurement; network analysers; automatic network analyzer; calibration; one-wafer devices; two-port error correction; two-port reciprocal network; waveguide system; Calibration; Coaxial components; Connectors; Error correction; Measurement standards; Performance analysis; Scattering parameters; Testing; Transmission line matrix methods; Waveguide components;
fLanguage
English
Journal_Title
Microwave and Guided Wave Letters, IEEE
Publisher
ieee
ISSN
1051-8207
Type
jour
DOI
10.1109/75.173410
Filename
173410
Link To Document