DocumentCode :
810467
Title :
Generation and Diagnosis of TW/cm2 Electron Beams
Author :
Pellinen, D.G. ; Heurlin, S.E.
Author_Institution :
Physics International Company San Leandro, California 94577
Volume :
20
Issue :
3
fYear :
1973
fDate :
6/1/1973 12:00:00 AM
Firstpage :
333
Lastpage :
335
Abstract :
Our experiments have demonstrated reasonably conclusively that electron beams in the 20-30 kA range at approximately 1 MeV can be focused into spots on the order of 1 mm in diameter or smaller to give electron beam densities as high as 2.7 MA/cm2. We have confirmed this measurement by several independent diagnostic techniques. We have also determined that the beam current is space charge limited and appears to follow the parapotential law Ip = R/d Ia¿o ln[¿o+(¿o2-1)1/2] Since the critical current is only proportional to R/d · ¿o, the ratio of Idiode/Icritical (for a given R/d) will become larger at a rate ln[¿o + (¿o - 1)1/2. This strongly suggests that the beam will self focus even more intensely at higher voltages. A limited number of tests at 3.MeV have indicated beam core spots smaller than 1/2 mm, the smallest we have observed to date. Our tests imply that an extension to AURORA-size beams (12 MeV) is feasible and would result in dramatic increases in delivered power together with further reduction in beam area.
Keywords :
Acceleration; Anodes; Cathodes; Circuit testing; Critical current; Current measurement; Electron beams; Electron emission; Glass; Voltage;
fLanguage :
English
Journal_Title :
Nuclear Science, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9499
Type :
jour
DOI :
10.1109/TNS.1973.4327114
Filename :
4327114
Link To Document :
بازگشت