• DocumentCode
    811539
  • Title

    A Wide Band Current Monitor Based on Pulsed Transformer Techniques

  • Author

    Sutter, D.F.

  • Author_Institution
    National Accelerator Laboratory Batavia, Illinois 60510
  • Volume
    20
  • Issue
    3
  • fYear
    1973
  • fDate
    6/1/1973 12:00:00 AM
  • Firstpage
    665
  • Lastpage
    667
  • Abstract
    A charged-particle beam current monitor has been designed using a coaxial cable transmission line in a configuration similar to that employed in building toroidal-wound wide band impedance matching and balun transformers. Several sizes of the coax-wound monitors have been constructed and compared with units of similar ferrite core material and geometry that were wound with ordinary magnet wire. One of the transformers has been used by experimenters at the NAL Internal Tarqet area since August of 1972. In order to simplify electronic signal processing, only average circulating charge is measured. This is done by measuring the "zero"signal" base-line shift due to the natural L/R response of the transformer.
  • Keywords
    Buildings; Coaxial cables; Coaxial components; Ferrites; Impedance matching; Magnetic materials; Monitoring; Pulse transformers; Transmission lines; Wideband;
  • fLanguage
    English
  • Journal_Title
    Nuclear Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9499
  • Type

    jour

  • DOI
    10.1109/TNS.1973.4327211
  • Filename
    4327211