  • Abstract
    Two main coil failures in a one-year period initiated a review of on-line protective circuitry. Two existing circuits, which would limit damage, were made more reliable. Four new circuits were added to monitor coil condition and protect against voltage transients.
  • Keywords
    Circuit testing; Coils; Condition monitoring; Laboratories; Protection; Resistors; Switches; Switching circuits; Synchrotrons; Voltage;